Error Code: C-2443 Follow
Code
C-2443
Classification
Main body: TCR sensor/C initial adjustment abnormality (high density)
Cause
When the initial adjustment is performed with the TCR sensor/C (TCRS4), the output value of TCRS4 exceeds the prescribed value.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing motor/C (M7)
- TCR sensor/C (TCRS4)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check TCRS4, and clean or repair it when there is dirt or any abnormality. (Wiring diagram: Main body (2/5): 23-F)
- Check the developing section, and clean or repair it if there is a sensor dirt or any abnormality.
- Check the connector connection between PRCB and TCRS4, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and M7, and the wiring. Then repair it when there is any abnormality.
- Rotate M7 with the IO Check (50-10) and other method. Then repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 19-E)
- Replace TCRS4.
- Replace M7.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment