Error Code: C-2712 Follow
Code
C-2712
Classification
Main body: High voltage unit/2 abnormality
Cause
An error detection signal of the 1st transfer/M is detected while the 1st transfer/M is active. The signal is detected even after you activate and deactivate the 1st transfer/M for a prescribed time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- High voltage unit/2 (HV2)
- 1st transfer roller/M
- Printer control board (PRCB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection of the high voltage contact of the process unit, and clean or repair it when there is any abnormality.
- Check the connector connection between HV2 and the 1st transfer unit, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (3/5): 7-M)
- Check the connector connection between PRCB and HV2, and the wiring. Then repair it when there is any abnormality.
- Replace HV2.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment