Error Code: C-2801 Follow
Code
C-2801
Classification
Main body: Gamma correction abnormality
Cause
The output voltage of the IDC sensor/Fr (IDCS1) or IDC sensor/Rr (IDCS2) is detected more than the specified value on the patch/Y of the developing DC maximum output.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing unit/Y
- IDC sensor/Fr (IDCS1)
- IDC sensor/Rr (IDCS2)
- IDC sensor shutter solenoid (SD4)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check the installation of the developing unit, and repair or replace it when there is an abnormality.
- Check the IDC sensor and clean it if the sensor is dirty.
- Check the IO Check (05-06) of IDCS1, and repair or replace it when there is any abnormality.
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the IO Check (05-12) of IDCS2, and repair or replace it when there is any abnormality.
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the connector connection between PRCB and IDCS1, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and IDCS2, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (55-00) of SD4 and repair or replace it when there is any abnormality.
- Replace IDCS1 or IDCS2.
- Replacing the developing unit.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment