Error Code: C-2834 Follow
Code
C-2834
Classification
Main body: Dot diameter correction abnormality
Cause
The proper value cannot be figured out within the specified time by the correction of the dot diameter correction/K.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Developing unit/K
- IDC sensor/Fr (IDCS1)
- IDC sensor/Rr (IDCS2)
- IDC sensor shutter solenoid (SD4)
- Writing unit/K
- Image processing board (IPB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 10 and solution 14.
- When the results are normal, perform following solutions other than solution 14.
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check that the writing unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check the installation of the developing unit, and repair or replace it when there is an abnormality.
- Check the IDC sensor and clean it if the sensor is dirty.
- Check the IO Check (05-06) of IDCS1, and repair or replace it when there is any abnormality.
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the IO Check (05-12) of IDCS2, and repair or replace it when there is any abnormality.
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the connector connection between PRCB and IDCS1, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and IDCS2, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between the writing unit and IPB, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (55-00) of SD4 and repair or replace it when there is any abnormality.
- Replace IDCS1 or IDCS2.
- Replacing the developing unit.
- Replace IPB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment