Error Code: C-2850 Follow
Code
C-2850
Classification
Main body: IDC sensor/Fr base correction reflected light quantity abnormality
Cause
On the IDC sensor/Fr (IDCS1) base correction, it is detected that the IDC sensor/Fr (IDCS1) output value is other than the specified range for specified times in a row. Alternatively, the LED applied voltage is out of the specified value for specified times in a row.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- IDC sensor/Fr (IDCS1)
- Intermediate transfer belt
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the process unit is correctly installed without looseness, and reinstall or repair it when there is any abnormality.
- Check that the belt cleaner blades the intermediate transfer section is not curled and reinstall or repair it when there is any abnormality.
- Check the intermediate transfer belt, and clean or replace it if there is any dirt or abnormality.
- Check the IDC sensor and clean it if the sensor is dirty.
- Check the connector connection between PRCB and IDCS1, and the wiring. Then repair it when there is any abnormality.
- Replace IDCS1.
- Replace PRCB.
- Replace IDCS1 and PRCB at a time.
Faulty part isolation DIPSW
Control during the detachment