Error Code: C-3904* Follow
Code
C-3904*
Classification
Main body: Fusing belt edge low temperature abnormality (hardware detection)
Cause
The fusing temperature sensor/2 (TH2) detects an error signal continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Fusing unit
- Printer control board (PRCB)
- Fusing heater lamp/2 (L2)
- Fusing temperature sensor/2 (TH2)
- Thermostat/2 (TS2)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it when there is any abnormality.
- Check the connector connections between TH2 and PRCB, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 8-H)
- Check the conduction of the TS2, and repair it when there is any abnormality.
- Check the activation and deactivation by the installation condition of L2 and L3, or the IO Check (45-00), repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-G)
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the installation condition of the TH2 and the temperature of the IO Check (45-12) and others, and adjust it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-H)
- Replace TH2.
- Replace TS2.
- Replace the fusing heater lamp assy/Up.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment