Error Code: C-3902* Follow
Code
C-3902*
Classification
Main body: Fusing belt central section low temperature abnormality (hardware detection)
Cause
The fusing temperature sensor/1 (TH1) detects an error signal continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Fusing unit
- Printer control board (PRCB)
- Fusing heater lamp/1 (L1)
- Fusing temperature sensor/1 (TH1)
- Thermostat/1 (TS1)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it when there is any abnormality.
- Check the connector connections between TH1 and PRCB, and the wiring. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 8-H)
- Check the conduction of TS1, and repair it when there is any abnormality.
- Check the activation and deactivation by the L1 installation condition or the IO Check (45-00), repair it when there is any abnormality. (Wiring diagram: main body (1/5): 3-F)
- Note
- The output check on the IO check mode has restrictive conditions. Check the IO check mode list before the output check.
- Check the installation condition of TH1 and the temperature of IO Check (45-11) and others and adjust it when there is any abnormality. (Wiring diagram: Main body (1/5):3-H)
- Replace TH1.
- Replace TS1.
- Replace the fusing heater lamp assy/Up.
- Replace PRCB.
Faulty part isolation DIPSW