Error Code: C-4103 Follow
Code
C-4103
Classification
Main body: Polygon motor abnormality
Cause
When the polygon motor/C (M22) in the writing unit is booted, the lock signal of M22 is not detected within a specified period of time. Alternatively, after the boot process, it is detected continuously for a specified period of time that a lock signal of M22 becomes inactive.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Polygon motor/C (M22)
- Printer control board (PRCB)
- DC power supply/2 (DCPS2) (AC57V130##, AC58V130## (C4070: Japan))
- Writing unit/C
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the writing unit, and replace it when there is any abnormality.
- Check the connector connection between PRCB and the writing unit, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between DCPS2 and the writing unit, and the wiring. Then repair it when there is any abnormality.
- Check IO Check (32-02) of M22, and replace the writing unit when there is any abnormality.
- Replace the writing unit.
- Replace PRCB.
- Replace DCPS2.
Faulty part isolation DIPSW
Control during the detachment