Error Code: C-4680 Follow
Code
C-4680
Classification
Main body: Color registration correction abnormality during the image diagnosis
Cause
The front door opened during the color registration correction of the image diagnosis, or SCs such as C-45xx and C-46xx that are related to other color registration abnormalities are detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- -
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- If any of the front doors had opened during the image diagnosis, close all the front doors, and conduct the image diagnosis again.
- Execute [Service Mode] - [Machine Adjustment] - [Printer Adjustment] - [Color Registration Auto. Adj.].
- If an error occurs, resolve it according to the error type. (Color Registration Auto.Adj. (Printer Adjustment))
- When you retry the image diagnosis and the error is detected again, store the log in either of the following measures.
- · [Service] - [Log Store] - [Execute Log Storing] - [Log+IQ Image Manual Store]
- · [UTILITY] - [System Information] - [Store Log & IQ Image]
- Report it with that log to KMBT.
Note
- Do not deactivate and activate the main power until you acquire the log data.
Faulty part isolation DIPSW
Control during the detachment