Error Code: C-4715 Follow
Code
C-4715
Classification
Main body: Index sensor abnormality (M)
Cause
When the machine executes APC, the Index sensor output does not change. Polygon mirror does not rotate. The index sensor failed to detect the laser because the position of the index sensor is improper or because the index sensor is defective.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Writing unit/M
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2 and solution 4.
- When the results are normal, perform solution 2 and solution 3.
- Check the connector connection between IPB and the writing unit, and the wiring. Then repair it when there is any abnormality.
- Replace the writing unit.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment