Error Code: C-4728 Follow
Code
C-4728
Classification
Main body: Image processing board abnormality
Cause
The power is not supplied, initialization abnormality, device abnormality, or the board is not installed
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- When you perform the IO Check (99-70) and the results for IPB are abnormal, perform the following steps.
- Check the installation status of IPB, and repair or replace it when there is an abnormality.
- Check the connector connection and the wiring on IPB, and repair it when there is any abnormality. (Wiring diagram: Main body (3/5): 3-G)
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment