Error Code: C-4730 Follow
Code
C-4730
Classification
Main body: Out of register abnormality
Cause
VTOP signals are input twice or more for 1 page. Alternatively, input timing of the VTOP signal is not normal.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Wiring (AC57N104)
- Image processing board (IPB)
- Printer control board (PRCB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please call service" is displayed on the panel.
Solution
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB.
- When the results are OK: Go on to the following steps.
- When the result is NG: There is an abnormality in IPB or the connection. Go on to the step 5.
- Prior check
- Check that the CN5402 of IPB is correctly connected.
- Check the connector connection between PRCB and IPB, CN107 of PRCB, and the wiring. Then repair it when there is any abnormality.
- Replace the wiring.
- Replace IPB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment