Error Code: C-47A8 Follow
Code
C-47A8
Classification
Main body: Beam pitch abnormality (C)
Cause
- When the malfunction code occurs during the gamma auto adjustment operation: Color registration adjustment value abnormality.
- When the malfunction code occurs during the color registration auto adjustment operation: Polygon drive system abnormality, sensor system abnormality, or printer clock system abnormality.
- When the malfunction code occurs during the output operation: Non-volatile abnormality
- When the malfunction code occurs during the first printing after you changed the adjustment value of the Beam Pitch Adjustment: Adjustment value abnormality, writing unit abnormality.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Semiconductor laser relay wiring (AC57N265)
- Writing unit/C
- Image processing board (IPB)
- NVRAM board (NRB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
<When abnormality occurs during the gamma auto adjustment operation>
- Carry out the beam pitch adjustment.
- Carry out the color registration auto adjustment.
- Carry out the gamma auto adjustment.
<When abnormality occurs during the color registration auto adjustment operation>
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB and the writing unit/C (laser drive board/C (LDB3)).
- When the result of IPB is NG: There is an abnormality in IPB or the connection. Go on to the step 5.
- When the result of the writing unit/C is NG: There is an abnormality in LDB3 or the connection. Go on to the following steps.
- Prior check
- Close the toner supply door properly.
- Close the front door properly. (Check with the IO Check (25-00) of the front door sensor (PS31).)
- The color registration auto adjustment is completed normally.
- Check the connector connection between IPB and LDB3, CN2100 of IPB, CN1812 of LDB3, and the wiring. Then repair it when there is any abnormality.
- Replace the writing unit/C.
- Replace IPB.
<When abnormality occurs during the output operation>
- Check the connector connection of NRB, and repair it when there is any abnormality.
- Replace NRB.
<When the malfunction code occurs during the first printing after you changed the adjustment value of the Beam Pitch Adjustment>
- When you input an inappropriate large value (example: +50, -100) to the Beam Pitch Adjustment: Configure the adjustment value of the Beam Pitch Adjustment to 0 once. Then, perform the Beam Pitch Adjustment again with the correct procedure (using the test chart).
- When you input an appropriate value to the Beam Pitch Adjustment with the correct procedure (using the test chart): Replace the writing unit/C.
Faulty part isolation DIPSW
Control during the detachment