Error Code: C-47AD Follow
Code
C-47AD
Classification
Main body: PolyTOP detection abnormality (K)
Cause
During the image formation with the PolyTOP, a PolyTOP error is detected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Writing unit/K
- Image processing board (IPB)
- Printer control board (PRCB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB and the writing unit/K (laser drive board/K (LDB4)).
- When the result of IPB is NG: There is an abnormality in IPB or the connection. Go on to the step 6.
- When the result of the writing unit/K is NG: There is an abnormality in LDB4 or the connection. Go on to the following steps.
- Prior check
- Close the toner supply door properly.
- Close the front door properly. (Check with the IO Check (25-00) of the front door sensor (PS31).)
- Check the connector connection between PRCB and the polygon motor/K (M23), CN130 of PRCB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and IPB, CN153 of PRCB, CN5500 of IPB, and the wiring. Then repair it when there is any abnormality.
- Replace the writing unit/K.
- Replace IPB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment