Error Code: C-4902 Follow
Code
C-4902
Classification
Main body: Thread DMA abnormality
Cause
When a timeout occurs in image data transfer.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please call service" is displayed on the panel.
Solution
- Prior check
- When an abnormal code occurs, be sure to deactivate and activate the main power of both the main body and the controller.
- Reconnect or replace the cable between the controller and the UK-301.
- Reconnect or replace the communication cable that is connected to the image processing board (IPB) and the controller.
- The firmware for the image control system, the controller, and the network control is the latest.
- When you connect an external controller, be sure that the latest firmware and patch are applied. In addition, DIPSW 114-3 must be "1".
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB.
- When the result of IPB is NG: There is an abnormality in IPB or the connection.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment