Error Code: C-4982 Follow
Code
C-4982
Classification
Main body: DMA16 (YMCK) VV length abnormality
Cause
The input image size that is notified by the controller and the image size that is actually transferred (YMCK-VV length) does not match.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Prior check
- The cable is connected between the controller and the main body.
- The power of the controller is not deactivated. Reconnect the communication cable that is connected to the image processing board (IPB).
- The firmware for the image control system, the controller, and the network control is the latest.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment