Error Code: C-5014 Follow
Code
C-5014
Classification
Main body: PF system control circuit communication error (sending)
Cause
PF system control circuit communication error (sending).
A checksum error occurs in a data that is sent to the control circuit.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- PF drive board (PFDB, PFUDB)
- Printer control board (PRCB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection and the wiring between the main body and PF, and repair it when there is any abnormality.
- PF-602m: Check the connector connection between PFDB and PRCB, and the wiring. Then repair it when there is any abnormality.
- PF-707m: Check the connector connection between PFUDB and PRCB, and the wiring. Then repair it when there is any abnormality.
- PF-602m: Replace PFDB.
- PF-707m: Replace PFUDB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment