Error Code: C-5008 Follow
Code
C-5008
Classification
Main body: Printer control board 5 V abnormality
Cause
Printer control board (PRCB) 5 V DC abnormality
An error signal is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- DC power supply/2 (DCPS2) (AC57V130##, AC58V130## (C4070: Japan))
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Disconnect CN100 on PRCB, boot the main body, and check the 5 V output of CN100-1.
- Replace PRCB when the output is 5 V.
- Check the connector connection between PRCB and DCPS2, CN100 of PRCB, CN4PU2 of DCPS2, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection of PRCB, CN107 of PRCB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection of DCPS2, CN2PU2 of DCPS2, and the wiring. Then repair it when there is any abnormality.
- Check each of the sensors that are connecting. Then repair or replace it when there is any abnormality.
- Replace PRCB.
- Replace DCPS2.
Faulty part isolation DIPSW
Control during the detachment