Error Code: C-5307 Follow
Code
C-5307
Classification
Main body: Fan abnormality
Cause
When the power supply cooling fan/2 (FM3) is active, an error detection signal of FM3 is detected continuously for a specified period of time. An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately to deactivate the main relay.
Estimated abnormal parts
- Printer control board (PRCB)
- Power supply cooling fan/2 (FM3)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Rotate the FM3 with the IO Check (42-00) or by hand. Then, repair or replace it when there is any abnormality. (Wiring diagram: Main body (1/4): 12-J)
- Check the connector connection and the wiring between PRCB and FM3, and repair it when there is any abnormality.
- Replace the FM3.
- Replace PRCB.