Error Code: C-5310 Follow
Code
C-5310
Classification
Main body: Fan abnormality
Cause
When the exhaust fan/Rr (FM14) is active, an error detection signal of FM14 is detected continuously for a specified period of time. An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Exhaust fan/Rr (FM14)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Rotate FM14 by hand or the IO Check (42-36), and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 14-I)
- Check the connector connection between PRCB and FM14, and the wiring. Then repair it when there is any abnormality.
- Replace FM14.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment