Error Code: C-5404 Follow
Code
C-5404
Classification
Main body: Fan abnormality
Cause
When the power supply cooling fan/1 (FM2) is active, an error detection signal of FM2 is detected continuously for a specified period of time. An error detection signal is detected continuously while you retry power feed several times. Alternatively, when the FM2 is rotating at a low speed, an abnormality is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Power supply cooling fan/1 (FM2)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Rotate FM2 by hand or the IO Check (42-20), and repair or replace it when there is any abnormality. (Wiring diagram: Main body (3/5): 12-J)
- Check the connector connection between IPB and FM2, and the wiring. Then repair it when there is any abnormality.
- Replace FM2.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment