Error Code: C-5311 Follow
Code
C-5311
Classification
Main body: Fan abnormality
Cause
When the Exhaust fan/Fr (FM15) is active, an error detection signal of FM15 is detected continuously for a specified period of time. An error detection signal is detected continuously while you retry power feed several times.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Exhaust fan/Fr (FM15)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Rotate FM15 by hand or the IO Check (42-37), and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 14-I)
- Check the connector connection between PRCB and FM15, and the wiring. Then repair it when there is any abnormality.
- Replace FM15.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment