Error Code: C-6104 Follow
Code
C-6104
Classification
Main body: Scanner startup abnormality
Cause
Connection with the scanner section cannot be confirmed.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
- Scanner drive board (SCDB)
- CCD board (CCDB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2, solution 3, solution 4, and solution 8.
- When the results are normal, perform following solutions other than solution 8.
- Check the connector connection between CCDB and IPB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between SCDB and IPB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between IPB and OACB, and the wiring. Then repair it when there is any abnormality.
- Replace CCDB.
- Replace SCDB.
- Replace OACB.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment