Error Code: C-6114 Follow
Code
C-6114
Classification
Main body: Scanner abnormality
Cause
The paper passes from the DF and during the initial move operation from the home position. In addition, within a specified period of time after the CIS cleaning motor (M7) becomes active, the CIS cleaning sensor (PS9) does not become inactive. In the other case, on home position search, within a specified period of time after M7 becomes active, PS9 does not become active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
- DF control board (DFCB)
- CIS cleaning motor (M7)
- CIS cleaning sensor (PS9)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 3, solution 4, and solution 9.
- When the results are normal, perform following solutions other than solution 9.
- Check the connector connection between M7 or PS9 and DFCB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between DFCB and IPB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between IPB and OACB, and the wiring. Then repair it when there is any abnormality.
- Replace PS7.
- Replace M7.
- Replace DFCB.
- Replace OACB.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment