Error Code: C-6103 Follow
Code
C-6103
Classification
Main body: Scanner abnormality
Cause
The scanner home sensor (PS201) becomes active during the period from the execution of the preparative scan command and the scan preparation command until the execution of the scan reference position move command.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
- Scanner drive board (SCDB)
- Scanner motor (M201)
- Scanner home sensor (PS201)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 5, solution 6, and solution 11.
- When the results are normal, perform following solutions other than solution 11.
- Check the drive section of the scanner (the wire, the pulley, the gear and the belt), and repair or replace it when there is any abnormality.
- Move to [Machine Adjustment] - [Scan Adjustment] - [Sensor Check] to check the condition of PS201, and repair or replace it when there is any abnormality.
- Check the connector connection between PS201 or M201 and SCDB, and the wiring. Then repair it when there is any abnormality. (Refer to Main body (3/5): 19-J, 20-J)
- Check the connector connection between SCDB and IPB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between IPB and OACB, and the wiring. Then repair it when there is any abnormality.
- Replace PS201.
- Replace M201.
- Replace SCDB.
- Replace OACB.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment