Error Code: C-6105 Follow
Code
C-6105
Classification
Main body: Communication error
Cause
The initial communication with the scanner is not completed within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2 and solution 4.
- When the results are normal, perform following solutions other than solution 4.
- Check the connector connection between OACB and IPB, and the wiring. Then repair it when there is any abnormality.
- Replace OACB.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment