Error Code: C-6712 Follow
Code
C-6712
Classification
Main body: Image processing board abnormality
Cause
The image processing board cannot be detected in the configuration process of the image processing board at the startup.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB.
- When the results are OK: Go on to the following steps.
- When the result is NG: There is an abnormality in IPB or the connection.
- Prior check
- Check if there is any problem with the connector connection of IPB.
- Replace the overall control board (OACB) and the image processing board (IPB) at the same time.
- Execute the IO Check (99-98).
Faulty part isolation DIPSW
Control during the detachment