Error Code: C-6753 Follow
Code
C-6753
Classification
Main body: IR image processing ASIC clock input malfunction trouble (back side)
Cause
During the scanning of the back side, the image processing ASIC register is read and written, but the write value and the read value do not match.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- CIS module (CIS)
- Image processing board (IPB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2 and solution 4.
- When the results are normal, perform following solutions other than solution 4.
- Check the connector connection between IPB and CIS, and the wiring. Then repair it when there is any abnormality.
- Replace CIS.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment