Error Code: C-6754 Follow
Code
C-6754
Classification
Main body: CIS clamp adjustment abnormality
Cause
After the gain adjustment at the startup is executed, the clamp adjustment value of one of each color and each channel of RGB is 0 or 255.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- CIS module (CIS)
- Image processing board (IPB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2 and solution 4.
- When the results are normal, perform following solutions other than solution 4.
- Check the connector connection between IPB and CIS, and the wiring. Then repair it when there is any abnormality.
- Replace CIS.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment