Error Code: C-6F02 Follow
Code
C-6F02
Classification
Main body: Scanner sequence abnormality 2
Cause
Even after a specified period of time after the DF starts the original reading operation, it is not completed.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please call service" is displayed on the panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 3 and solution 6.
- When the results are normal, perform following solutions other than solution 6.
- Check the connector connection between DFCB and SCDB, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between SCDB and IPB, and the wiring. Then repair it when there is any abnormality.
- Replace DFCB.
- Replace SCDB.
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment