Error Code: C-7106 Follow
Code
C-7106
Classification
Main body: Printer control board ICP blowout
Cause
When a specified period of time elapses after the power becomes active, an error detection signal of ICP4 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
Correction
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between PRCB and the paper feed clutch/1 (CL1), CN114 of PRCB, CN378 (Relay connector), CN376 (Relay connector), CN334 of CL1, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and the paper feed clutch/2 (CL2), CN114 of PRCB, CN375 (Relay connector), CN373 (Relay connector), CN344 of CL2, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and the pre-registration clutch/1 (CL3), CN114 of PRCB, CN378 (Relay connector), CN376 (Relay connector), CN335 of CL3, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and the pre-registration clutch/2 (CL4), CN114 of PRCB, CN375 (Relay connector), CN373 (Relay connector), CN345 of CL4, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and the intermediate conveyance clutch/1 (CL5), CN108 of PRCB, CN330 (Relay connector), CN325 of CL5, and the wiring. Then repair it when there is any abnormality.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment