Error Code: C-7115 Follow
Code
C-7115
Classification
Main body: Printer control board ICP blowout
Cause
When a specified period of time elapses after the power becomes active, an error detection signal of ICP24 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
Correction
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between PRCB and the tacking fan/1 (FM19), CN116 of PRCB, CN273 (Relay connector), CN259 of FM19, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and the tacking fan/3 (FM21), CN116 of PRCB, CN273 (Relay connector), CN257 of FM21, and the wiring. Then repair it when there is any abnormality.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment