Error Code: C-7204 Follow
Code
C-7204
Classification
Main body: Conveyance drive board ICP blowout
Cause
When a specified period of time elapses after the power becomes active, an error detection signal of ICP3 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Conveyance drive board (CDB)
Correction
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between CDB and the decurler motor (M44), CN170 of CDB, CN444 of M44, and the wiring. Then repair it when there is any abnormality.
- Replace CDB.
Faulty part isolation DIPSW
Control during the detachment