Error Code: C-7206 Follow
Code
C-7206
Classification
Main body: Conveyance drive board ICP blowout
Cause
When a specified period of time elapses after the power becomes active, an error detection signal of ICP5 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Conveyance drive board (CDB)
Correction
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Check the connector connection between CDB and the loop motor (M42), CN171 of CDB, CN390 (Relay connector), CN447 of M42, and the wiring. Then repair it when there is any abnormality.
- Replace CDB.
Faulty part isolation DIPSW
Control during the detachment