Error Code: C-8106 Follow
Code
C-8106
Classification
DF: DF lift-up motor abnormality (Down)
Cause
Within a specified period of time after the DF lift-up motor (M5) rotates reversely, the DF lift-up lower limit sensor (PS3) does not become active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- DF lift-up lower limit sensor (PS3)
- DF lift-up motor (M5)
- DF control board (DFCB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the original feed section, and repair it when there is any abnormality.
- Check the connector connection between PS3 or M5 and DFCB, and the wiring. Then repair it when there is any abnormality.
- Check the drive or coupling of the gear of M5, and repair it when there is any abnormality. (Wiring diagram: DF: 5-C)
- Check PS3, and repair it when there is any abnormality. (Wiring diagram: DF: 10-C)
- Replace PS3.
- Replace M5.
- Replace DFCB.
Faulty part isolation DIPSW
Control during the detachment