Error Code: C-9403 Follow
Code
C-9403
Classification
Main body: Exposure lamp lighting abnormality or scanner connector disconnected
Cause
When paper is passed from DF: It is detected that the CIS output is the standard value or less in the CIS gain adjustment. Alternatively, the scanner connector is disconnected.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- CIS module (CIS)
- Image processing board (IPB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Clean the CIS.
- Clean the white reference side on the CIS side.
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 4 and solution 6.
- When the results are normal, perform following solutions other than solution 6.
- Check the connector connection between CIS and IPB, and the wiring. Then repair it when there is any abnormality.
- Replace CIS.
- Replace IPB.
Faulty part isolation DIPSW