Error Code: C-9701 Follow
Code
C-9701
Classification
Main body: Surface flat cable disconnection detection
Cause
The CCD cable is either disconnected or has come off.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
- CCD cable (AA2JN145)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Prior check
- Check the connector connections on the overall control board (OACB).
- Check CN2400 of IPB and the wiring. Then repair it when there is any abnormality.
- Replace the CCD cable.
- Replace the overall control board (OACB).
- Replace the image processing board (IPB).
Faulty part isolation DIPSW
Control during the detachment