Error Code: C-C102 Follow
Code
C-C102
Classification
Main body: Printer control communication abnormality
Cause
When the receiving from the printer control is completed, either error is detected; (1) data checksum error or (2) communication GA produces an error vector (parity, framing or brake detection). Alternatively, within a specified period of time after the sending is started, the sending does not complete.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Printer control board (PRCB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Perform the IO Check (99-70) and check if there is a problem with IPB.
- When the results are abnormal, perform solution 2 and solution 3.
- When the results are normal, perform following solutions other than solution 3.
- Check the connector connection between IPB and PRCB, and the wiring. Then repair it when there is any abnormality.
- Replace IPB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment