Error Code: C-D0FC Follow
Code
C-D0FC
Classification
Main body: SSD abnormality
Cause
An abnormality occurs in the SSD (SSD).
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Interface cable (ACMHN271)
- Interface cable (ACMHN272)
- Interface cable (ACMHN274)
- Power cable (ACMHN273)
- SSD (SSD)
- Overall control board (OACB)
- Image processing board (IPB)
- HDD interface board (HDDIFB)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Execute the IO Check (99-03) of SSD bad sectors check and recovery.
- Conduct the Format SSD All Data. (Refer to Format SSD All Data)
- Replace OACB and SSD. (Refer to Overall control board (OACB), SSD (SSD))
- Replace the wiring.
- Replace IPB.
- Replace HDDIFB.
Faulty part isolation DIPSW
Control during the detachment