Error Code: C-E002 Follow
Code
C-E002
Classification
Main body: Message and method parameters invalid
Cause
The parameter value exceeds the permissible range.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Replace IPB.
- Replace OACB.
Faulty part isolation DIPSW
Control during the detachment