Error Code: C-E005 Follow
Code
C-E005
Classification
Main body: Memory access abnormality
Cause
Memory access abnormality.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
- Overall control board (OACB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Deactivate the sub power switch and the main power switch, and then unplug the power plug. Then Restart the main body after 10 seconds.
- Reinstall the firmware (I, P, and C).
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB.
- When the results are OK: Go on to the step 5.
- When the result is NG: There is an abnormality in IPB or the connection. Go on to the following steps.
- Replace IPB.
- Replace OACB.
Faulty part isolation DIPSW
Control during the detachment