Error Code: C-E008 Follow
Code
C-E008
Classification
Main body: Output paper density automatic adjustment abnormality
Cause
An error is detected during the output paper density adjustment.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Image processing board (IPB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Replace IPB.
Faulty part isolation DIPSW
Control during the detachment