Error Code: C-E009 Follow
Code
C-E009
Classification
Main body: Paper interval processing error
Cause
When the image effective signal of the normal image output or the test pattern output is active, the effective signal of the belt, the patch and the registration becomes active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Wiring (AC57N104)
- Image processing board (IPB)
- Printer control board (PRCB)
Correction
Deactivate and activate the sub power switch (SW2) of the main body.
Note
- The message "Please turn on power again" is displayed on the touch panel.
Solution
- Prior check
- Check that the CN5402 of the overall control board (OACB) is correctly connected.
- Execute the IO Check (99-70) of the board self-diagnosis. Check the results of IPB/M.
- When the results are OK: Go on to the following steps.
- When the result is NG: There is an abnormality in IPB/M or the connection. Proceed to solution 5.
- Check the connector connection between PRCB and IPB, CN107 of PRCB, CN54002 of IPB, and the wiring. Then repair it when there is any abnormality.
- Replace the wiring.
- Replace IPB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment