Error Code: C-2221 Follow
Code
C-2221
Classification
Main body: 1st transfer pressure release abnormality
Cause
The pressure release initial operation, pressure operation, release operation of the 1st transfer roller are not completed within a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- DC power supply/2 (DCPS2) (AC57V130##, AC58V130## (C4070: Japan))
- Printer control board (PRCB)
- 1st transfer pressure release motor (M10)
- 1st transfer pressure sensor/1 (PS50)
- 1st transfer pressure sensor/2 (PS51)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the 1st transfer fusing pressure release section, and clean or repair it when there is any abnormality.
- Check the connector connection between PRCB and PS50, PS51, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between PRCB and M10, and the wiring. Then repair it when there is any abnormality.
- Check the connector connection between DCPS2 and PRCB, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (48-00) and others of M10 and the coupling of the gear, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 22-N)
- Check the operation with IO Check (48-00) of PS50 and PS51 and others, and repair or replace it when there is any abnormality. (Wiring diagram: Main body (2/5): 22-N)
- Replace PS50.
- Replace PS51.
- Replace M10.
- Replace DCPS2.
- Replace PRCB.
- Replace M10 and DCPS2 at a time.
Faulty part isolation DIPSW
Control during the detachment