Error Code: C-3102 Follow
Code
C-3102
Classification
Main body: Motor abnormality
Cause
During the pressing operation: Within a specified period of time after the fusing pressure release motor (M47) becomes active, the fusing pressure position sensor/2 (PS25) or the fusing pressure position sensor/3 (PS26) does not become active. During the release operation: Within a specified period of time after M47 becomes active, the fusing pressure position sensor/1 (PS24) does not become active.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Fusing pressure release motor (M47)
- Fusing pressure position sensor/1 (PS24)
- Fusing pressure position sensor/2 (PS25)
- Fusing pressure position sensor/3 (PS26)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the front door is closed properly, and repair it when there is any abnormality.
- Check the fusing unit, and repair it when there is any abnormality.
- Check the fusing drive gear system, and repair it when there is any abnormality.
- Check the connector connection between M47, PS24, PS25, PS26, and the PRCB, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (47-05) and others of M47 and the coupling of the gear. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-M)
- Check IO Check (47-05) of PS24, IO Check (47-06) of PS26, IO Check (47-07) of PS25 and the operation of PS24, PS25, PS26, and repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-L, 3-M)
- Replace PS24, PS25 and PS26.
- Replace M47.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment