Error Code: C-3104 Follow
Code
C-3104
Classification
Main body: Motor abnormality
Cause
When the fusing pressure release motor (M47) is active, 2 or more of the following sensors become active: the fusing pressure position sensor/1 (PS24), the fusing pressure position sensor/2 (PS25) and the fusing pressure position sensor/3 (PS26).
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Fusing pressure release motor (M47)
- Fusing pressure position sensor/1 (PS24)
- Fusing pressure position sensor/2 (PS25)
- Fusing pressure position sensor/3 (PS26)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check that the front door is closed properly, and repair it when there is any abnormality.
- Check the fusing unit, and repair it when there is any abnormality.
- Check the fusing drive gear system, and repair it when there is any abnormality.
- Check the connector connection between M47, PS24, PS25, PS26, and PRCB, and the wiring. Then repair it when there is any abnormality.
- Check the IO Check (47-05) and others of M47 and the coupling of the gear. Then repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-M)
- Check IO Check (47-05) of PS24, IO Check (47-06) of PS25, IO Check (47-07) of PS26 and the operation of PS24, PS25, PS26, and repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 3-L, 3-M)
- Replace PS24, PS25, or PS26.
- Replace M47.
- Replace PRCB.
Faulty part isolation DIPSW