Error Code: C-3302 Follow
Code
C-3302*
Classification
Main body: Fan abnormality
Cause
When the fusing belt exhaust fan (FM9) is active, an error detection signal of FM9 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Fusing belt exhaust fan (FM9)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between FM9 and PRCB, and the wiring. Then repair it when there is any abnormality.
- Rotate FM9 by hand or the IO Check (42-03) and other methods. Then repair it when there is any abnormality. (Wiring diagram: Main body (2/5): 7-I)
- Replace FM9.
- Replace PRCB.
- Replace FM9 and PRCB at the same time.
Faulty part isolation DIPSW
Control during the detachment