Error Code: C-3304* Follow
Code
C-3304*
Classification
Main body: Fan abnormality
Cause
When the fusing separation fan/1 (FM10) is active, an error detection signal of FM10 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Fusing separation fan/1 (FM10)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between FM10 and PRCB, and the wiring. Then repair it when there is any abnormality.
- Rotate FM10 by hand or the IO Check (42-22) and other methods. Then repair it when there is any abnormality. (Wiring diagram: Main body (2/5): 6-I)
- Replace FM10.
- Replace PRCB.
- Replace FM10 and PRCB at the same time.
Faulty part isolation DIPSW
Control during the detachment