Error Code: C-3308* Follow
Code
C-3308*
Classification
Main body: Fan abnormality
Cause
When the fusing intake fan (FM13) is active, an error detection signal of FM13 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Printer control board (PRCB)
- Fusing intake fan (FM13)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connector connection between FM13 and PRCB, and the wiring. Then repair it when there is any abnormality.
- Rotate FM13 by IO Check (42-32) or manually, and repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 12-J)
- Replace FM13.
- Replace PRCB.
- Replace FM13 and PRCB at the same time.
Faulty part isolation DIPSW
Control during the detachment