Error Code: C-3303 Follow
Code
C-3303
Classification
Main body: Fan abnormality
Cause
When the fusing roller cooling fan/1 (FM33) is active, an error detection signal of FM33 is detected continuously for a specified period of time. When the fusing roller cooling fan/2 (FM34) is active, an error detection signal of FM34 is detected continuously for a specified period of time.
Measures to take when an alert occurs
The main body and the option stop immediately.
Estimated abnormal parts
- Conveyance drive board (CDB)
- Printer control board (PRCB)
- Fusing roller cooling fan/1 (FM33)
- Fusing roller cooling fan/2 (FM34)
Correction
Note
- The message "Please call service" is displayed on the panel.
Solution
- Check the connection between the rear side connector of the fusing unit and the main body side connector, and repair it when there is any abnormality.
- Check the connector connection between FM33, FM34, CDB and PRCB, and the wiring. Then repair it when there is any abnormality.
- Rotate FM33, FM34 by IO Check (42-15) or manually, and repair it when there is any abnormality. (Wiring diagram: Main body (1/5): 9-O)
- Replace FM33 and FM34.
- Replace CDB.
- Replace PRCB.
Faulty part isolation DIPSW
Control during the detachment